Manuals
airvo 2 user manual

airvo 2 user manual

The Airvo 2 is a compact, portable nasal high flow system designed for delivering Optiflow NHF therapy, with adjustable flow rates from 2 to 60 L/min.

This user manual provides essential guidance for healthcare professionals and patients to ensure safe and effective use of the device.

Compliance with the manual is critical for optimal performance and patient safety, adhering to medical standards and manufacturer recommendations.

Overview of the Airvo 2 Device

The Airvo 2 is a compact, portable nasal high flow system with an integrated flow generator, delivering Optiflow NHF therapy across a range of settings. It provides adjustable flow rates from 2 to 60 L/min, ensuring precise and efficient respiratory support for patients. The device is designed for use in various care environments, from hospitals to home care, and is supported by a comprehensive user manual to guide healthcare professionals and patients in its safe and effective operation.

Importance of the User Manual

The Airvo 2 user manual is essential for safe and effective device operation. It provides critical safety precautions, usage guidelines, and troubleshooting tips. Reading and adhering to the manual is crucial for healthcare professionals and patients to ensure optimal performance and prevent potential risks or injuries. Proper understanding guarantees effective therapy delivery.

Target Audience: Healthcare Professionals and Patients

The Airvo 2 user manual is designed for healthcare professionals and patients. It provides detailed instructions for setup, operation, and troubleshooting, ensuring safe and effective use. Guidelines are included for both groups to maximize therapy benefits. Adherence is crucial for optimal performance and safety, covering necessary aspects for use.

Key Features and Benefits

  • Compact, lightweight design for easy portability.
  • Adjustable flow rates from 2 to 60 L/min.
  • Optiflow Nasal High Flow therapy for enhanced comfort.
  • Integrated controls for precise therapy customization.

Compact Design and Portability

The Airvo 2 features a lightweight, compact design, enhancing portability for use in various care settings. Its small footprint and mobility make it ideal for hospital and home environments, ensuring effective therapy delivery without compromising functionality.

  • Lightweight for easy transport.
  • Suitable for both hospital and home care.
  • Compact size allows for convenient placement.
  • Maintains high performance despite its portability.

Adjustable Flow Settings (2-60 L/min)

The Airvo 2 offers precise flow rate adjustment from 2 to 60 L/min, ensuring personalized therapy for various patient needs. This wide range supports both low and high-flow therapies, making it versatile for different clinical scenarios and patient conditions.

  • Adjustable flow rates for tailored therapy.
  • Suitable for a broad range of patient needs.
  • Precision control for optimal treatment outcomes.
  • Ease of operation for healthcare professionals.

Optiflow Nasal High Flow Therapy

The Airvo 2 delivers Optiflow Nasal High Flow (NHF) therapy, providing heated, humidified air to enhance patient comfort and respiratory support; Designed for both adult and pediatric use, it promotes natural breathing patterns, reduces respiratory effort, and improves oxygenation, making it ideal for various clinical settings and patient conditions.

  • Delivers heated, humidified air for comfort.
  • Supports natural breathing patterns.
  • Reduces respiratory effort and improves oxygenation.
  • Versatile for adult and pediatric care.

Safety Guidelines

Ensure the Airvo 2’s air openings are never blocked and avoid placing it on soft surfaces. Always follow the user manual to prevent injury and ensure safe operation.

Important Safety Precautions

Never block the Airvo 2’s air openings or place it on soft surfaces like beds, as this may obstruct airflow and compromise functionality. Always ensure proper ventilation and adhere to the user manual’s guidelines for safe operation. Failure to comply may result in injury or device malfunction. Follow all warnings and manufacturer recommendations carefully to ensure patient safety and optimal performance.

Contraindications and Warnings

The Airvo 2 is contraindicated for patients with severe respiratory failure or those requiring invasive ventilation. Use with caution in patients with unstable medical conditions. Improper use or ignoring warnings may result in injury. Certain lot numbers (pre-August 14, 2017) were recalled due to speaker configuration issues. Always consult healthcare professionals for specific patient suitability.

Proper Use and Handling

To ensure safe and effective use, never block the Airvo 2’s air openings or place it on soft surfaces like beds. Always position the device on a stable, flat surface. Regularly inspect the unit and accessories for damage. Use only approved patient interfaces and follow the user manual for proper operation and maintenance.

Technical Specifications

The Airvo 2 features a flow rate of 2-60 L/min, an integrated flow generator, and sensors for temperature, flow, and oxygen, all calibrated to strict limits. It is compatible with approved patient interfaces.

Flow Rate Range and Operating Conditions

The Airvo 2 supports a flow rate range of 2 to 60 L/min, suitable for various patient needs. It operates effectively under standard environmental conditions, ensuring reliable performance across different care settings. The device’s sensors and controls are designed to maintain consistent flow delivery, enhancing patient comfort and therapy outcomes. Proper operating conditions are essential for optimal functionality.

Compatibility with Patient Interfaces

The Airvo 2 is compatible with Fisher & Paykel’s range of patient interfaces, including Optiflow nasal cannulas and other approved accessories. Proper interface selection ensures safe and effective therapy delivery. Always use interfaces tested and recommended by Fisher & Paykel to maintain device performance and patient safety.

Humidification and Temperature Control

The Airvo 2 incorporates advanced humidification and temperature control systems, ensuring precise delivery of heated, humidified air. This feature enhances patient comfort and reduces the risk of airway irritation, making it suitable for continuous use in various care settings.

Installation and Setup

Unbox and inspect the Airvo 2 for damage, then connect accessories and sensors as outlined. Place the device on a stable surface and power it on.

Unboxing and Initial Inspection

Carefully unbox the Airvo 2 device and inspect for any visible damage or tampering. Verify all components, including the flow generator, chamber, tubing, and patient interfaces, are included. Ensure the device and accessories are clean and free from defects before proceeding with setup.

Check the lot number to confirm compatibility with the user manual. If any damage or missing items are found, contact Fisher & Paykel Healthcare support immediately. Proper inspection ensures safe and effective operation of the device. Refer to the manual for detailed unpacking instructions.

Connecting Accessories and Sensors

Connect the tubing, patient interface, and other accessories securely to the Airvo 2 device as outlined in the user manual. Ensure sensors are properly attached for accurate flow rate and temperature monitoring. Use only approved Fisher & Paykel interfaces and accessories to maintain optimal performance. Verify all connections are secure before operation.

Refer to the manual for specific instructions on attaching the nebulizer adapter or other optional components. If unsure, contact Fisher & Paykel support for assistance. Proper connection ensures safe and effective therapy delivery. Always follow the manufacturer’s guidelines for accessory compatibility and setup.

Placement and Powering On the Device

Place the Airvo 2 on a stable, flat surface away from soft materials to ensure proper airflow. Avoid blocking air openings or placing it on beds. Plug in the device and ensure the power source is secure. Turn it on following the manual’s instructions. Always refer to the user manual for detailed guidance.

Operating Instructions

Start the Airvo 2 by powering it on and setting the desired flow rate. Adjust settings as needed and monitor the patient’s response to therapy.

Starting the Device and Setting Up Therapy

Power on the Airvo 2 and ensure all connections are secure. Check for any alarm notifications and resolve them before proceeding. Connect the patient interface and set the flow rate according to clinical needs. Use the control panel to adjust settings and monitor therapy parameters. Always refer to the user manual for detailed startup procedures.

Adjusting Flow Rates and Monitoring Patients

Adjust the Airvo 2 flow rates using the control panel, ensuring settings match clinical requirements. Continuously monitor the patient’s comfort, oxygen saturation, and respiratory status. Check for proper interface fit and address any signs of discomfort or distress. Refer to the user manual for guidance on alarm responses and troubleshooting during therapy.

Using the Device in Different Care Settings

The Airvo 2 is versatile, suitable for use in hospitals, clinics, and home care. Its portability and adjustable flow rates make it ideal for various patient needs. Ensure proper setup and monitoring in all settings, adhering to the user manual guidelines for safe and effective therapy delivery across different environments.

Maintenance and Disinfection

Regular cleaning and disinfection are essential for maintaining the Airvo 2’s performance and patient safety. Follow the manual’s guidelines for proper procedures and schedules.

Cleaning Procedures and Disinfection Guidelines

Regular cleaning involves using a soft, dry cloth and mild detergent, avoiding harsh chemicals. Disinfection requires following specific guidelines in the manual, including flow rate settings of 30 L/min for 30 minutes. Ensure the device is dry before reuse. Follow all instructions carefully to maintain optimal performance and patient safety.

Replacing Parts and Consumables

Replace standard parts every 12 months or as indicated by the user manual. The AirSpiral tube should be replaced every 6 months or if damaged. Use only Fisher & Paykel-approved consumables to ensure optimal performance and patient safety. Always refer to the manual for specific instructions and contact support if unsure.

Regular Maintenance for Optimal Performance

Regularly clean and disinfect the device as per guidelines to prevent contamination. Check for wear and tear on tubing and patient interfaces, replacing them as needed. Ensure all connections are secure and functioning properly. Follow the recommended maintenance schedule in the user manual to guarantee reliable operation and patient safety. Contact Fisher & Paykel support for assistance.

Troubleshooting Common Issues

Identify and resolve common issues by checking alarm codes, verifying device connections, and ensuring proper sensor functionality. Refer to the manual or contact Fisher & Paykel support for assistance.

Alarm Codes and Solutions

Refer to the alarm codes in the manual to identify issues like low flow rates or sensor malfunctions. Check power connections, ensure proper sensor function, and clean or replace faulty parts. Restart the device after addressing the issue. If problems persist, contact Fisher & Paykel Healthcare support for assistance.

Device Malfunction and Repair

In case of malfunction, check power supply, sensors, and connections. For issues like faulty alarms or software glitches, restart the device or update software. If problems persist, contact Fisher & Paykel Healthcare for professional repair. Ensure devices from recalled batches are addressed by the manufacturer to maintain safety and functionality.

Resolving Connectivity Problems

Check all connections and ensure accessories are compatible. Restart the device and verify proper interface placement. For unresolved issues, contact Fisher & Paykel Healthcare support. Ensure devices from recalled batches are updated, as connectivity issues may stem from outdated configurations or faulty components.

Accessories and Compatibility

The Airvo 2 is compatible with specific patient interfaces, tubing, and accessories. Use only approved components to ensure proper functionality and patient safety.

  • Patient interfaces and tubing must meet specified standards.
  • Disinfection kits are available for maintenance and hygiene.

Available Accessories for Airvo 2

  • Disinfection kits for maintenance and hygiene.
  • Tube and chamber kit with nebulizer adapter.
  • Patient interfaces and compatible tubing.
  • Accessories specifically designed for Optiflow therapy.

Use only approved accessories to ensure proper functionality and patient safety.

Ensuring Compatibility with Other Devices

Verify all accessories and patient interfaces are Fisher & Paykel Healthcare-approved for Airvo 2.

  • Use only tested and compatible tubing and interfaces.
  • Consult the manual for validated device combinations.
  • Contact Fisher & Paykel Healthcare for specific compatibility questions.

Proper compatibility ensures optimal performance and patient safety.

Approved Patient Interfaces and Tubing

Use only Fisher & Paykel Healthcare-approved interfaces and tubing with the Airvo 2.

Optiflow nasal interfaces and compatible tubing are designed for optimal therapy delivery.

Heated or non-heated options are available.

Always check the manual or contact support for compatibility questions.

Using approved accessories ensures proper safety and effectiveness.

Regulatory Information

The Airvo 2 complies with medical standards and regulations.

Contact Fisher & Paykel Healthcare for updates or recalls.

Units with LOT numbers 130621 and above are covered.

Adherence to manual guidelines ensures compliance.

Compliance with Medical Standards

The Airvo 2 adheres to stringent medical standards, ensuring safety and efficacy. It meets regulatory requirements for respiratory devices, with rigorous testing conducted by Fisher & Paykel Healthcare. Compliance is verified through controlled manufacturing processes and quality assurance protocols, guaranteeing reliability for healthcare professionals and patients. Proper use as per guidelines is essential.

Voluntary Recall Notices and Updates

Fisher & Paykel Healthcare issued a voluntary recall for Airvo 2 devices manufactured before August 14, 2017, due to a speaker configuration issue. Users are advised to contact the manufacturer for assistance. Regular updates and notifications ensure compliance and safety, maintaining trust in the device’s performance and reliability.

Contacting Fisher & Paykel Healthcare Support

For inquiries, contact Fisher & Paykel Healthcare at Tel: 64 9 574 0100 or Fax: 64 9 574 0158. Visit their website for regional offices and support details. Ensure timely assistance for troubleshooting, repairs, and updates to maintain optimal device performance and patient care.

The Airvo 2 user manual is essential for safe and effective therapy delivery. Adherence to guidelines ensures optimal performance and patient safety. Contact Fisher & Paykel Healthcare for further assistance.

The Airvo 2 user manual provides critical guidance for healthcare professionals and patients, emphasizing safety, proper use, and maintenance. Key features include adjustable flow rates, Optiflow NHF therapy, and portability. Regular disinfection, troubleshooting, and adherence to guidelines ensure effective and safe therapy delivery. Always follow instructions to maintain optimal device performance and patient outcomes.

Final Tips for Effective Use

Always ensure the Airvo 2 is properly disinfected and maintained. Regularly check for software updates and follow the manual’s guidelines. Use only approved accessories to maintain performance. Monitor patient comfort and adjust settings as needed. Keep the device on a stable surface and avoid blocking air vents for optimal functionality and safety.

Importance of Adhering to the Manual

Adhering to the Airvo 2 user manual is critical for ensuring patient safety and optimal device performance. Failure to follow guidelines may result in injury or device malfunction. Always read and comply with warnings, and keep the manual accessible for future reference to maintain therapeutic efficacy and operational integrity.